Modelling
Timber systems: stud walls, joist floors, CLT walls
#Timber systems: stud walls, joist floors, CLT walls
Nextra Design has three timber systems that you describe as a whole instead of element by element. The engine builds each one into the model for the analysis and designs it to EN 1995-1-1. The app saves them in the same form as the desktop program:
- a stud wall: a timber-frame wall made of studs, plates, sheathing boards and their fasteners. The engine designs the racking, the studs, the sheathing and the hold-downs.
- a joist floor: joists on a load panel. The joists are not FE members. The engine designs one representative joist for bending, shear, bearing, deflection and vibration, and puts the joists' own weight on the panel.
- a CLT wall: a cross-laminated timber shear wall with its base connections (bearing, angle brackets, hold-downs). The engine checks overturning, sliding, buckling and drift.
Open them with Library → Timber systems (on a phone: Model in the bottom bar, the Library tab, then the Library button → Timber systems). Each tab lists the model's walls or floors, with Edit, Delete and New …. Every change is one step, so one Undo takes it back. Before anything is saved, the app runs the same check the engine makes, and a value that cannot be used shows its reason in red.
All three are drawn in the 3D view (Display › Timber systems turns them off):
- a stud wall as its sheathing with the openings cut out, the bottom and top plates and the studs at their spacing;
- a joist floor as its joists;
- a CLT wall as a panel.
#A stud wall in the view

A stud wall is one object. Click it in the view (tap it on a phone) and it opens in Timber systems. The wall is
coloured in the selection colour and named in the view (SW1 · stud wall). There you can change any of its values and
press Apply, or Delete it. A click through an opening goes to whatever is behind the wall.
After Preview wall model (below), the view draws the engine's parts of each wall on top of it, coloured by role: plates dark brown, end studs almost black, studs light brown, braces as orange dashes. These parts are what the analysis uses. The model itself still holds only the wall.

#Stud walls

- New stud wall. The name is suggested (SW1 …).
- Where: a stud wall stands vertically on a level base line. Choose how to give it:
- Two points: start and end of the base line. Type them, pick a point…, or copy a member or slab edge with Along. Or Draw in the view (2 clicks): click the start, then the end of the wall in the view (snaps work; on a phone the view comes forward). The wall is made at once with the height and the rest of the form; its base is level at the start's height. Esc cancels.
- Corner points: a wall on each side of an outline. Tick Closed to add a wall from the last corner back to the first. The walls are numbered on from the name (SW1, SW2 …).
- Selected beams: select one or more horizontal members in the view first. You get one wall along each beam, under it (the top of the wall at the beam) or on it.
- Slab edges: one wall under (or on) each edge of a slab.
- under the slab: the top of each wall is at the slab and the base is the height below it.
- on the slab: the base of each wall is at the slab.
- Height in metres.
- Studs:
- b × h: b along the wall, h through the wall, in mm. Or pick a rectangular Model section.
- Spacing in metres.
- Grade: C24, GL24h and the other grades of the EC5 library, or a model material with one of those grades.
- End studs: how many studs stand side by side at each wall end and beside each opening. They carry the hold-down force.
- Sheathing and fasteners:
- Board: OSB, plywood, particleboard or cement board from the library.
- Thickness and Sides (one face or both faces).
- Fastener: a library nail or screw, or a plain nail with d and length.
- Spacing along the sheet edges. The intermediate studs get twice that spacing.
- Openings (one wall only): u0 to u1 along the wall from the start point, z0 (sill) to z1 (head) above the base. A door has its sill at 0. Openings must lie inside the wall and must not overlap. An opening cannot take the whole length of the wall.
- How it is modelled:
- Model:
- Automatic: the engine's default, equivalent braces.
- A · shear panel: the sheathing as a membrane between the studs.
- B · equivalent braces: diagonals with the wall's racking stiffness.
- C · detailed: studs, sheathing shells, and fastener links between them.
- Carries: racking only, or racking and vertical loads.
- Base:
- automatic is "on the structure below" when members run along the base line; otherwise the engine adds the supports itself (held horizontally, hold-downs at the end studs).
- supported here always adds those supports.
- on the structure below never does.
- Top: automatic ties the top plate to the beams above when members run along the top line.
- Model:
- Add stud wall (or Add walls for an outline or a slab).
#Preview wall model

Once the model is a project (after your first edit; projects save themselves; until then the dialog says "Save the model as a project to preview…"), Preview wall model asks the engine what the stud walls of the saved revision turn into. Your model is not changed. The preview belongs to the walls and to the beams along their base and top lines (the ones the automatic base and top tie them to): change a wall or move such a beam, and it says the preview is out of date. For each wall it lists:
- the members by role: plates, end studs, studs and braces (or the sheathing surfaces in modes A and C);
- the supports, and how many of them sit on springs (hold-downs, bearings);
- the links (fasteners, plate slip);
- the engine's notes, for example "top auto -> connect (on B1)", the nailing it assumed for an unspecified plate connection, and that tension-only braces make the run non-linear.
#Convert a stud wall to elements
Under each wall of the preview, Convert SW1 to elements turns what the engine builds into ordinary elements of your model, in one undo step: the studs, plates and braces become members (with their releases, sections and buckling lengths), sheathing panels become surfaces with the material the engine gives them, the supports and hold-downs become supports (on their springs), and the fastener and plate-slip links, springs, materials and sections are added. Points within the model's tolerance of an existing point use that point. The stud wall itself goes: from then on you edit the parts one by one (no stud wall design). Undo brings the wall back.

Edits are saved within a moment. If you change a wall after a preview, the app asks you to preview again.
#Joist floors
A joist floor sits on a load panel, which gives its outline and its area loads per load case. Make the panel first under Loads → Load panels.
- New joist floor. The name is suggested (JF1 …).
- Floor:
- On the load panel: pick the panel.
- Joists run: along the long side, along the short side, or at an angle from the panel's first edge.
- Spans: one simple span, or continuous over a number of equal spans. A continuous floor also gets span-by-span imposed load patterns.
- Joists:
- b × h in mm, an I-joist (the FJI range of ETA-02/0026), or a Model section (rectangle, composite or I-joist).
- Spacing in metres.
- Grade. Particleboard and cement board cannot be joists.
- Decking:
- (EI)b across the joists (kNm²/m) and Floor mass (kg/m²) feed the vibration check of EN 1995-1-1 7.3.3. The mass defaults to the panel's permanent loads.
- Tick The decking acts as the joist's top flange to design the joist as a composite section (gamma method, EN 1995-1-1 Annex B). It needs a library fastener or Kser, and works only with rectangular joists.
- Add joist floor.
#CLT walls
- New CLT wall. The name is suggested (CW1 …).
- Where: the base line (level) and the Height. Give the line as for a stud wall.
- Panel:
- Layup from the EC5 library. "CLT 140 5s (40-20-20-20-40)" is 140 mm thick in 5 layers. The outer layers run vertically and carry the load.
- Grade: CLT-C24 or CLT-T14, or a model material with a CLT grade.
- Base:
- The wall is supported here: the engine adds a compression-only bearing, the brackets and the hold-downs. Or the wall sits on the structure below.
- Bears on: concrete, or a timber floor (give the floor grade).
- Hold-downs at each end: the first at c from the edge, how many per end, their spacing, their stiffness K (empty = rigid) and the design resistance Rd of one end (empty = not checked). They must stay within their half of the wall.
- Shear brackets: how many, K each (empty = a rigid base) and Rd each.
- Add CLT wall.
Hold-downs act in tension only and the bearing in compression only, so a model with a supported CLT wall runs non-linear.
#On a phone

The same dialog opens from the Library tab on a phone. Every form fits the screen width.
#What was checked against the engine
Every value the app accepts was run through the real engine: schema validation, reference checks, the stud wall preview and build, the CLT wall build, the joist check, and the FE idealisation. Every library grade was also tried in every role, so each list offers only what the engine can use. The app refuses some values the engine would take but build wrongly:
- a sloping base line (the engine would build the wall flat at the start height);
- openings outside the wall or overlapping each other;
- hold-downs reaching past the middle of a CLT wall;
- a steel profile as a plate section (zero-size plates);
- a joist floor outline with fewer than three corners.
#Connections (dowels, bolts, screws, nails)
Library › Materials › Connections defines a fastener group where members meet: select the members that meet (their common point is found), choose dowels, bolts, screws or nails, the diameter, rows and fasteners per row, the spacings a1 / a2 and the distances a3,t / a4,c (and the length for screws and nails), then Add connection. Edit and Remove work on the list. The connection is part of the model (it travels in the .nxd to Nextra Design) and the design run checks it to EN 1995-1-1 section 8: the Johansen failure modes, the effective number n_ef of fasteners in a row, the minimum spacings and distances, block shear and splitting. A screw or nail in single shear counts only the length that reaches the main member (l − t1). Steel plates, moment connections and the EC3 kinds use the same model data; their form follows.