Skip to content
Nextra

Results and design

Run the analysis, read the results

#Run the analysis, read the results

The app follows Nextra Design's order: Analyse → Analysis runs the analysis; Analyse → Results shows what it found (forces, displacements, reactions); Design → Design runs the code checks and shows the utilisation. An analysis on its own never colours members by utilisation: that comes only from Run design.

On a computer the groups Model · Analyse · Design · Toolkit are on top, the tabs of the open group in the row under them, and the commands and settings of the tab in the ribbon below. On a phone the groups are in the bottom bar and the tabs at the top of the panel.

#Run the analysis

Analyse › Analysis: the analysis type, Run linear static and its status; the view shows the model only

Analyse → Analysis → Run linear static sends the project to the Nextra Design engine: every load case solved once, every combination and envelope by superposition, in a few seconds. A model that is not a project yet becomes one first; projects save themselves (Getting started). The status says Finished with the time, or why it failed. When it finishes the app opens Results. If the structure can move without resistance, Type: Model check finds the mechanisms and can repair them (Model check).

The run card: the engine's stage and progress, in the middle of the view

While it runs, a card in the middle of the view shows what the engine is doing and how far it is, as the engine reports it: Building the analysis model, Meshing · 40 slabs and walls, Factorising · 41,084 DOFs, 37 load cases, Solving, Global imperfections, then for Run design Design checks · 120 of 192 members and Design checks · 12 of 40 slabs and walls, and last Writing the results and Saving the results. The bar follows the engine's own progress; until the engine's first stage arrives it is an estimate from this project's last run of the same kind. The view stays usable under the card. If the connection drops (a phone that slept), the app says so; the run may still finish on the server.

Stop on the card ends the run: the engine stops within a second or so, nothing is saved, and the app says the run was stopped. The stopped run still counts as a run. Closing the page does not stop a run (it finishes on the server and its results are there when you come back).

#The model is locked while results are loaded

An edit after a run: the model is locked and asks first

As in Nextra Design, a finished run locks the model: the results on screen belong to exactly this model. The closed padlocks beside the project name show it (see The two lock buttons). An edit (a move, a delete, a new section, an Undo, an assistant's edit) then asks first:

  • Unlock and apply: the edit goes in. The results stay on screen marked the model changed: run again, and the next edit does not ask.
  • Keep the results: the edit is not made; the model and its results stay as they were.

There are two locks. Changing only design fields (design code, service class, buckling lengths, deflection limits and the other design attributes) needs no new analysis: it leaves the analysis lock alone and asks only when design results are shown (Discard the design and apply). Any other edit voids both. Unlock in Analyse › Analysis › Status unlocks without an edit. While a run is going every edit waits for it. To edit freely after every run, untick Lock the model while results are loaded in Display.

#The two lock buttons and Refresh

Beside the project name: Refresh, the Analysis lock and the Design lock (both open here: no results loaded)

Beside the project name are two lock buttons, as in Nextra Design:

  • Analysis (amber): a closed padlock while analysis results are loaded and match the model. Click it to unlock; the results are set aside and the icon becomes an open padlock. The next run locks it again.
  • Design (violet): the same for design results.

The round arrow before them is Refresh. It loads the latest saved revision of the project, for example after a change from your phone or from an assistant connected through ChatGPT. The app also does this by itself when the tab is idle. Refresh the model is in the project menu too.

#The results

Analyse › Results: the |e| displacement as a colour contour on the undeformed shape, the legend in the view, the settings in the ribbon

After a run the view shows the total displacement |e| as a colour contour on the undeformed shape, with its legend in the corner of the view. The ribbon holds every setting, as in AxisVM's result toolbar:

  • Load case: the group (load cases, ULS or SLS combinations, envelopes) and the one to show.
  • Result: displacement eX, eY, eZ or |e| [mm], member forces N, Vy, Vz [kN], T, My, Mz [kNm], or, with slabs and walls, surface forces nx, ny, nxy, mx, my, mxy, qx, qy (below).
  • Display: Line (the deflected line, or the Member diagram for a force), Contour, or None.
  • Shape: Undeformed or Deformed, and the scale. An envelope has no deformed shape. A contour or a deformed shape is the model: the members and slabs are drawn as the result, not under it. Original geometry (off by default) adds the undeformed model, faint, behind it.

Deformed with the contour: the result is the model

Original geometry on: the undeformed model faint behind the deformed result

With Solid on (left bar), the result is drawn on the members' real sections: the contour on the section, and a deformed shape bends the sections themselves.

Solid: the contour on the real sections

Solid and Deformed: the sections in the deformed shape (here exaggerated 10×)

  • Values: numbers on the members, off by default; switch them on for each element's max and min, or the model's.

#Slabs and walls

The tower: |e| on the slab and wall mesh, deformed, one legend with the members

A surface force: mx in kNm/m on the slabs and walls

Slabs and walls are drawn as their finite-element mesh (the elements the engine solved, with their edges) whenever the result is drawn as the model (a contour or a deformed shape), as in Nextra Design:

  • A displacement (eX, eY, eZ, |e|) colours the mesh by the value at each node, with the same legend as the members: one colour scale and one min / max for the whole model.
  • Deformed moves the mesh by the same scale as the members, so slabs, walls and members stay joined. The automatic scale takes the largest displacement of members and surfaces.
  • Surface forces (in the Result list when the model has slabs or walls): the resultants per metre nx, ny, nxy [kN/m], mx, my, mxy [kNm/m] and qx, qy [kN/m], in each element's local axes, for a load case, a combination or an envelope (Max, Min or Max & min). The engine gives one value per element; as in Nextra Design it is averaged to the nodes within each surface, so the contour is smooth inside a slab and keeps its jump where a wall meets a slab. The members are drawn plain grey meanwhile, and the legend is the surfaces' own. A surface force has no line diagram: it is always a contour.
  • With a member force, the slabs and walls are drawn plain grey (in the deformed shape when Deformed is on).

The panel gives the surfaces' largest and smallest value of the shown result; with Values on, the view marks both.

The panel lists the key figures (largest |My|, |Vz|, |N|, displacement) and, folded, each member's extremes and the support reactions. The choice stays while you work on other tabs; a new run starts again from the |e| contour. More on the diagrams: Result diagrams.

#Run design: the utilisation

Design › Design results after Run design: the utilisation colours with their legend in the view, the member table in the panel

On Design → Design the steps are Design attributes (the code values per member), Run design and Design results. Run design checks runs the Eurocode checks (EC3 steel, EC5 timber, EC2 concrete, and the codes of bamboo and earth) on the forces of the analysis, running it first when needed. Then:

  • All members pass or N member(s) fail, and umax, the highest utilisation: the governing check's demand divided by its resistance. Up to 1.0 the member is adequate; above 1.0 it fails.
  • Governing: the members with the highest utilisation and the check that governs each (buckling, bending, shear, crack width, deflection …).
  • Max displacement in mm, and equilibrium: the support reactions balance the loads. "NOT OK" means the model itself is wrong (see below), not that a member is too weak.
  • Each member and slab is coloured by its utilisation, from blue (little used) through green and yellow to red at 1.0; dark red above 1.0. The ribbon switches the colours off (Display: None) or shows u on the members (Values).

A column given a far too small section: it fails in buckling and is drawn dark red

#Concrete slabs and walls: reinforcement, crack width, punching

Design › Slabs: the required bottom reinforcement in x on the slab mesh

After Run design, the Design tab's Slabs list shows, on the slab and wall mesh with its own legend: A_s bottom x / y and A_s top x / y (the required reinforcement in mm²/m, Wood-Armer from every ULS combination and at least A_s,min, EN 1992-1-1 9.3.1.1), the crack width w_k (quasi-permanent, 7.3.4), the shear utilisation v_Ed / v_Rd,c (6.2.2) and the part not covered by the bars you gave. The panel names the largest value and lists the punching checks (6.4) at columns inside a slab.

To check given bars instead of designing them, select the slab and set, in Elements, Slab: bars bottom x (and y, top x, top y) as D12@150 (diameter @ spacing, mm) or an area in mm²/m, the cover and the crack width limit w_k; blank lets the engine design that layer.

#Deformation types: instantaneous, creep, final

Design results, Result w_net,fin: the timber members coloured by their net final deflection in mm, the legend 0 … 29.7 mm, and the panel showing w_net,fin = w1 + w2 + w3 − w_c with "Creep (long-term) included: yes"

The ribbon's Result also shows the deflection of the design checks split as Nextra Design does (EN 1990 A1.4.3, EN 1995-1-1 2.2.3). The engine writes three parts at the governing point of every deflection check, and each type is a sum of them:

Result What it is Formula
w1 elastic deflection of the sustained load G + ψ2·Q, instantaneous
w2 creep of the sustained load timber k_def·w1 (k_def from the service class); concrete φ·w1 + shrinkage (EN 1992-1-1 7.4.3); bamboo (1/C_DE − 1)·w1 (ISO 22156)
w3 elastic deflection of the rest of the variable load (1 − ψ2)·Q, instantaneous
w_inst (instantaneous) all loads, elastic: EC5 u_inst w1 + w3
w_creep (creep) EC5 u_creep w2
w_fin (final) EC5 u_fin = u_inst + u_creep w1 + w2 + w3
w_net,fin (net final) the final deflection less the pre-camber w_c w1 + w2 + w3 − w_c
w_add (additional) what happens after the finishes are fitted: creep and the whole variable load w2 + w3 + w1,Q
custom your own sum, typed in the panel e.g. 0.5 w2 + w3

With a type picked:

  • mm or u = w / limit. u is offered only when the type has a check of its own (timber: w_inst and w_net,fin; w_fin only with a pre-camber or its own limit; w_add only with its own limit; concrete and bamboo have their own checks, so their types are in mm). Without one, the value is read at the member's governing deflection check and shown in mm.
  • Display: Line colours each member by its value; Contour colours along each span (the value at every station); None switches the colours off. The legend runs from 0 to the largest value in mm.
  • Shape: Deformed bends the members by the chosen type (the largest value drawn at 5 % of the model size, × the scale). The deflection is relative to the ends of each span (the engine's span reference), so a joist is drawn sagging from where it sits on its beam; the beam's own sag is not added to it.
  • The panel shows the type as its parts, each named for the material (for timber "creep: k_def·w1 (k_def = 0.6)"), whether creep (long-term) is included, and per member the value, the check it was read at, the limit and the combination.
  • Values in the ribbon puts the number (mm, or u) on each member.

Result w_net,fin as a contour on the deformed shape: the purlins and rafters sag, blue at the supports, red at mid span

Result w_creep: only the creep part w2 = k_def·w1, 0 … 6.1 mm; the table shows each member's value and the check it comes from

What gets no deformation type (grey): steel (EC3 has no creep; its check is the characteristic w_inst only: pick Deflection checks (u) for it), the horizontal check w_h, and slabs and walls (the type is shown on members). The analysis results (Analyse → Results) are elastic and never contain creep.

#Other analysis types: second order, buckling, vibration

Analyse → Analysis → Type picks what the engine runs; the run button says which (Run buckling, Run modal). Every type runs on the saved model and opens Results when it finishes.

  • Buckling (α_cr): the elastic critical load factor of every load case and combination, and its first buckling modes (Modes, 1 to 20). EN 1993-1-1 5.2.1(3): with α_cr ≥ 10 a first-order elastic analysis is enough; below 10 second-order effects count; below 1 the structure buckles under the load itself.
  • Modal (vibration): the natural frequencies, periods and effective mass ratios in X, Y and Z of the first modes (the mass comes from the permanent loads).

Results after a buckling run: alpha_cr per load case, the verdict, and buckling mode 1 drawn on the model in magenta

The Buckling card on the Results tab gives the governing α_cr (green from 10, orange below), a row per load case and combination with its first factors, and buttons 1, 2, 3… that draw that buckling mode on the model (magenta, scaled to a tenth of the model size; press it again to hide it).

Results after a modal run: frequency, period and effective mass per mode

#Why the numbers can be trusted: Verification

Toolkit › Verification: textbook cases, the engine next to the hand formula

Toolkit → Learn and extend → Verification solves textbook cases with the same engine (simply supported beams, cantilevers, ...) and shows its answer next to the hand formula, the difference in % and the tolerance. All cases pass; the list is the same for everyone and is worked out once per engine version.

#When the model changes

Any edit, or unlocking the analysis with the padlock, sets the results aside: the view no longer draws them, the utilisation colours go back to normal, and Results says Results set aside; run the analysis or the design again. To compare, Show the old results anyway draws them once more, marked as old (Hide them puts them away). The result always belongs to one revision of the project (see History).

After unlocking: Results says the results are set aside and the view draws the model only

#Open results from Rhino (.nxr)

A model you analysed in Rhino with Nextra Design can show its results here without running again. Nextra Design writes a .nxr results folder next to the model (index.json and the .bin arrays): zip that folder (Windows: right-click › Send to › Compressed folder) and, on the saved project of the same model, choose Toolkit › File › Open results (.nxr). The Results tab opens with them, read-only, marked Imported from .nxr (not run here); the diagrams, the summary and the assistant read them as they read a run made here. They belong to the project's current revision: if the .nxr is of another model (its members or slabs are not this project's), or you edit the model afterwards, they are set aside as old results. An import counts as one run of your monthly allowance and is at most 24 MB; a damaged archive, or one that is not a .nxr folder, is refused and costs nothing.

#Make a failing member work

  1. Select it (Geometry, tap it): the panel shows its section, its length and its buckling lengths with their reasons.
  2. On Elements, tick Section and paint a larger one, or change the material; a library name you type (IPE, HEA, SHS, glulam, sawn timber …) is added to the model by itself.
  3. If buckling governs, check the buckling length: a brace or auto between restraints often helps more than a bigger section (Assign properties).
  4. Run design again.

#Troubleshooting

Message What it means What to do
"unknown section …" / "unknown material …" a name the engine does not know pick it from the list on Elements; type b x h (140x450), a profile (HEA200), a circle (D200) or a library name
"… is not a IPE profile in the catalogue" a profile size that does not exist use one from the suggestions (the Nextra Design library)
"equilibrium NOT OK", huge displacements, "mechanism" the structure can move without resistance: too few supports, or too many releases at one point add supports in all directions somewhere; release fewer ends; see Structural reference
"Member … has zero length" two ends on the same point delete it, or move a point
"Surface … is no longer flat" a slab corner was moved out of its plane move the other corners too
"… carry member loads and are not in line; move them first" Remove vertex between two loaded segments at an angle move or delete their loads first (Split, Divide, Reverse, Intersect, Join and Insert vertex take loads along)
"Changed elsewhere: reloaded" the project was changed in another tab, device or by an assistant your view now shows the latest; repeat your last edit if it is missing
a limit message (analyses per month, storage) your plan's limit is reached see Account; limits reset monthly
"Not saved: …" the project could not be made or saved (a limit, or no connection) the reason follows; move a project to the trash if you have too many, then edit again

Results are a design aid. A qualified engineer checks the model, the assumptions and the results before anything is built.