Skip to content
Nextra

Modelling

Load panels: roofs, walls and floor build-ups

#Load panels: roofs, walls and floor build-ups

A load panel is an area that is not part of the FE model. It carries the area loads you put on it (kN/m²) to the members around or under it, and then it is done: it adds no stiffness and no self-weight, and nothing is meshed. Use one for a roof on purlins or rafters, a wall under wind, or a floor build-up on beams. You don't need a slab for any of these. It is the same object as Nextra Design's load panel (and RFEM's load transfer surface or AxisVM's load panel), so the engine distributes it exactly as the desktop program does.

Open it with Loads → Load panels (on a phone: the Load settings button of the Loads tab, then Load panels).

#Make a panel

The panel editor: corners copied from the slab SL1, one-way at 90°, 1.5 kN/m² down in case G

  1. New roof panel, New wall panel or New floor panel (see Loads for the kinds and their preset loads). The name is suggested (RP1, WP1, FP1 …).
  2. Corners: tap a slab under From a slab to copy its corners, or type x, y, z (m) in the table. Add corner adds a row. The corners go in order around the panel. The edge from corner 1 to corner 2 is the panel's x axis, and the span angle is measured from it. The panel must be flat (within 1 mm) and its outline must not cross itself. If it is not, the editor says which corner is wrong.
  3. Distribution: how the load reaches the members (see below).
  4. Members found: which members take load.
    • within a distance: members within the distance of the panel plane. The default is 0.05 m, so a panel drawn on the beam level finds the beams.
    • nearest layer: the nearest members along the panel normal, at any distance. Use it for a roof drawn above its purlins.
    • along the load: the nearest members in the direction each load acts.
  5. Loads on the panel: one row per load case.
    • Case: one of the model's load cases.
    • Value in kN/m².
    • Direction:
      • global: along global z, per m² of panel. Negative = down, so −1.5 is 1.5 kN/m² downwards.
      • projected: along z, per m² of plan. Use it for snow on a sloping roof.
      • local: along the panel normal (+ = along the normal). Use it for wind pressure on a wall.
    • Given by: a value, wind: cpe × qp or snow: μ × s. Only one of them is stored (see Loads). Wind needs the model's wind pressure qp, and snow needs its snow load sk. The editor warns you if either is missing.
  6. Add panel (or Apply when you edit). The panel and its loads are one change, so one Undo takes it back.

The list shows each panel with its distribution, area and number of loads. Edit opens it again. Delete removes the panel and its loads.

#One-way, two-way or plate

How the load travels Use it for
Two-way Every piece of the panel goes to the nearest member (tributary areas; on a rectangle, the 45° rule). Floors and roofs supported on all sides.
One-way Along the span angle to the first member on each side, shared by the lever rule. Members parallel to the span get nothing. Decking, purlins, rafters, a slab spanning one way.
Plate The loads go on a fictitious plate held along its members, and the plate's reactions go to the members. Irregular panels, openings, panels not supported on all sides. It is slower.

Span angle (one-way only): degrees from the edge corner 1 → 2, turning anticlockwise seen from above. For a wall, look from the side its normal points to. 0 = along the first edge, 90 = across it. For the sample's slab, the first edge runs along x like the beams B1–B4, so 90 makes the load span across, onto the beams.

Joists + edge beams (one-way): the decking spans to the joists, which are the members across the span. Members along the span are edge beams, and they take a strip along them directly (Edge strip, default half the joist spacing).

#See where the load goes

The engine's tributary regions: each colour is the part of the roof one beam carries

In the 3D view each panel is a translucent orange area with a dashed outline and a label. A one-way panel is hatched along its span, with an arrow. The panel never gets in the way: taps go through it to the members and points, so you can still select or paint.

Once the model is a project (after your first edit; until then the dialog says "Save the model as a project to preview…"), Preview distribution asks the engine how it splits each panel. The answer is the same split the analysis uses:

  • In the 3D view, each member's region of the panel is drawn in its own colour, labelled with its area.
  • The dialog has a table with one row per member: the region's area and, for each load given as a value, area × value in kN. The total is the panel area × the load. For the sample (12 × 5 m, 1.5 kN/m²) that is 90 kN, about 22.5 kN on each beam.

The preview table next to the regions

Show in 3D folds the dialog into a small bar so you can look at the regions. Clear removes them. Once you change a panel, the old regions are no longer drawn: preview again. The preview reads the saved project, which is the latest revision after each change.

The areas are exact for two-way panels. For one-way panels they give each member's lever-rule total. For plate panels they are close. If a panel finds no member, the table says so: raise the distance or switch Members found to nearest layer. Otherwise the load would be lost.

#Then analyse

Analysis → Analyse runs the model with its panels (Read the results). The engine samples each panel (about every 0.1 m) and hands each sample's share to its members along their length (with the torsion of an eccentric panel).

#Select and delete a load

An area load selected: its arrows and sheet in the selection colour

Click a load's arrow to select it: point, line and area loads alike (for a point load, click the outer half of the arrow; the inner half belongs to the point). The load turns the selection colour and a note says what it is (type, value, case). Shift-click adds or takes out more; a selection box catches the loads in it too. Delete deletes the selected loads (Undo takes them back). A click on empty space clears the selection.

In Loads → Apply loads the card then shows the selected loads (type, case, X / Y / Z; "varies" where they differ) and changes them in place: Overwrite (the default) or Add to each load's own value, and a new case for all. See Selected members, slabs and loads. A load made by a load panel follows its panel: change the panel's loads (above), not the load itself.

Two line loads selected: Z varies (−5, −7); Add −1

#Panels that load members away from them

A panel whose own plane carries nothing, because it sends its load along its normal to members elsewhere (a plan outline on the ground under a curved roof, with nearest layer), is not drawn in the view. It shows only while it is selected (in the Load panels list), so no stray outline sits on the ground under the structure.