Files and export
Structural reference
#Structural reference
The essentials for modelling and checking in nextra.structuralweb, in one place. Values marked EN are the Eurocode
recommended values; a national annex (NA) can change them. The engine uses the annex set in the model settings
(national_annex, default EN). For preliminary design only where stated; final design needs a qualified engineer.
#Units and conventions
- Lengths and coordinates in m; forces in kN; moments in kNm; distributed loads kN/m and kN/m².
- Section sizes, slab and wall thickness, eccentricities in mm. E, G, fy, fck in N/mm² (MPa). Density in kg/m³.
- Global axes: Z is up. Gravity acts in −Z (g = 9.81 m/s²).
- Axial force N > 0 is tension. My > 0 gives tension at the −z fibre of the section.
- Member local x runs from start to end. Local z is the global Z projected onto the section plane; for vertical members
local y is along global X.
rollturns the section about local x. - Surface local x runs from corner 0 to corner 1 (turned by
axis_angle); local z is the normal, pointing up for non-vertical surfaces.
#Supports (six degrees of freedom)
A support fixes global translations and rotations, written as six digits ux uy uz rx ry rz; 1 = fixed, 0 = free.
| Support | fix |
Use |
|---|---|---|
| Fixed (clamped) | 111111 |
column base on a stiff foundation, cantilever root |
| Pinned | 111000 |
column base with an anchor-bolt connection, simple bearing in 3D |
| Roller in X | 011000 |
expansion bearing (free to slide in X) |
| Vertical only | 001000 |
bearing on a wall, needs other supports for stability |
A structure needs enough restraints for every rigid-body motion (3 translations, 3 rotations); otherwise the analysis reports a
mechanism. Springs (spring id) replace rigid digits with a stiffness.
#Local axes of a member
Releases, member loads in local directions, sections and results use the member's own axes. Select a member to see them (x red, y green, z blue, at its middle); Solid shows the section the same way round.
- x runs along the member, from its start to its end (Reverse direction swaps them).
- z points up for every member that is not vertical: global Z, made square to x. The section's depth
hlies along z, so an IPE beam stands upright. - y = z × x, sideways; the section's width
blies along y. - Vertical members (columns): y = x × global X, z = x × y. For a column drawn upwards, y is global Y and z points to −X.
- roll (degrees) turns y and z about x:
roll 90lays a beam on its side, a column turns its strong axis to the other direction. A reference vectorlocal_axissets z directly instead. - The rule is the engine's (Nextra Design), so the same model gives the same axes in Nextra Design, Rhino and here.

#Member end releases
Releases free internal forces at a member end, written as six local digits ux uy uz rx ry rz (the same order as
N, Vy, Vz, T, My, Mz); 1 = released, 0 = connected. Keywords: fixed (all connected), pinned, auto (default).
000011frees both bending moments at that end (a simply supported beam end in 3D, keeping torsion).000111frees torsion too.auto: beam-role members get pinned span ends, a cantilever root without a back span stays fixed, collinear beams joined end to end act as one continuous beam; other members follow the joint rule (timber pinned at joints, other materials rigid).- Releasing too much (for example torsion at both ends, or every end of a joint) makes a mechanism.
#Load cases and categories
Each load belongs to a load case; each case has a category that sets its partial and ψ factors. Category ids of the EN annex:
| Category id | Meaning | Typical imposed load (EN 1991-1-1, recommended) |
|---|---|---|
G |
permanent (self-weight, finishes) | — (self_weight: true adds members and surfaces automatically) |
A-floors |
domestic / residential floors | 1.5–2.0 kN/m² (EN 2.0) |
A-stairs |
stairs | 2.0 kN/m² |
A-balconies |
balconies | 2.5–4.0 kN/m² (EN 2.5) |
B-offices |
offices | 2.0–3.0 kN/m² (EN 3.0) |
C1-tables |
areas with tables (cafés, schools) | 2.0–3.0 kN/m² |
C3-no-obstacles |
areas without obstacles (halls) | 3.0–5.0 kN/m² |
D1-retail |
general retail | 4.0–5.0 kN/m² |
E1-storage |
storage | 7.5 kN/m² |
H-roof |
roofs not accessible except for maintenance | 0.0–1.0 kN/m² (EN 0.4) |
Snow |
snow | from EN 1991-1-3 and the site |
Wind |
wind | from EN 1991-1-4 and the site |
E-seismic |
seismic | from EN 1998 |
Use these exact ids (for example Wind, not W).
#Combinations (EN 1990)
With auto_combinations: true the engine builds the combinations from the cases and categories.
Ultimate limit state, persistent design situation (EN recommended):
- 6.10: 1.35 G + 1.5 Q₁ + Σ 1.5 ψ₀ Qᵢ
- 6.10a / 6.10b (the less favourable of): 1.35 G + Σ 1.5 ψ₀ Q — and — 0.85 × 1.35 G + 1.5 Q₁ + Σ 1.5 ψ₀ Qᵢ
- Favourable permanent load: γG = 1.0.
Serviceability: characteristic G + Q₁ + Σ ψ₀ Qᵢ; frequent G + ψ₁ Q₁ + Σ ψ₂ Qᵢ; quasi-permanent G + Σ ψ₂ Q.
ψ factors (EN 1990 Table A1.1):
| Category | ψ₀ | ψ₁ | ψ₂ |
|---|---|---|---|
| A domestic, B offices | 0.7 | 0.5 | 0.3 |
| C congregation, D shopping | 0.7 | 0.7 | 0.6 |
| E storage | 1.0 | 0.9 | 0.8 |
| H roofs | 0 | 0 | 0 |
| Snow (sites ≤ 1000 m) | 0.5 | 0.2 | 0 |
| Wind | 0.6 | 0.2 | 0 |
#Materials (common values)
| Material | Strength | E (N/mm²) | Weight |
|---|---|---|---|
| Steel S235 / S355 (EC3) | fy = 235 / 355 | 210 000 | 78.5 kN/m³ |
| Concrete C25/30, C30/37 (EC2) | fck = 25 / 30 | 31 000 / 33 000 (Ecm) | 25 kN/m³ reinforced |
| Glulam GL24h / GL28h (EC5) | fm,k = 24 / 28 | 11 500 / 12 600 (E0,mean) | about 4.2–4.6 kN/m³ |
| Softwood C24 (EC5) | fm,k = 24 | 11 000 | about 4.2 kN/m³ |
Name materials by grade (S355, C30/37, GL24h) with code EC3, EC2 or EC5; sections by profile (IPE300,
HEA200) or as rectangles (GL 140x450, RC 300x300) in mm.
#Utilisation and checks
- Utilisation u = design effect / design resistance. u ≤ 1.0 passes; the app shows u > 0.9 as close (amber) and
u > 1.0 as failing (red).
u_maxis the governing value of the model. - Check families: axial; bending + axial; buckling (flexural); lateral-torsional buckling (LTB); shear; torsion; deflection.
- Deflection limits are set by the annex and the project; common values: beams L/250 (quasi-permanent, total), L/300 to L/500 where brittle finishes or partitions are carried, cantilevers 2 × those (L/125 for L/250).
#Preliminary sizing (rules of thumb, preliminary only)
| Element | Depth ≈ |
|---|---|
| Steel I-beam, simply supported | span / 20 (IPE); span / 25 for light loads |
| Steel column, few storeys | HEA / HEB 200–300 for 3–4 m storey height and moderate loads |
| Concrete slab, one-way, simply supported | span / 25 to span / 30 |
| Concrete slab, two-way continuous | span / 35 |
| Concrete beam | span / 12 to span / 15 |
| Glulam beam, simply supported | span / 17 |
| Timber joist | span / 20 |
#Common modelling mistakes
- Members that cross without a shared point are not connected (unless
connect_crossingsapplies): use Intersect (Geometry → Edit) or place a point. - Coordinates within the tolerance (1 mm) are merged into one point on import; larger gaps stay separate members (Weld points merges them later).
- A slab must stay flat; moving one corner bends it (the app warns).
- Every material, section and load case used must be defined in the model.
- Missing horizontal restraint (all pinned bases and pinned beam ends) makes a mechanism.
- Loads on the wrong case category get the wrong factors (for example wind as