Skip to content
Nextra

Files and export

Structural reference

#Structural reference

The essentials for modelling and checking in nextra.structuralweb, in one place. Values marked EN are the Eurocode recommended values; a national annex (NA) can change them. The engine uses the annex set in the model settings (national_annex, default EN). For preliminary design only where stated; final design needs a qualified engineer.

#Units and conventions

  • Lengths and coordinates in m; forces in kN; moments in kNm; distributed loads kN/m and kN/m².
  • Section sizes, slab and wall thickness, eccentricities in mm. E, G, fy, fck in N/mm² (MPa). Density in kg/m³.
  • Global axes: Z is up. Gravity acts in −Z (g = 9.81 m/s²).
  • Axial force N > 0 is tension. My > 0 gives tension at the −z fibre of the section.
  • Member local x runs from start to end. Local z is the global Z projected onto the section plane; for vertical members local y is along global X. roll turns the section about local x.
  • Surface local x runs from corner 0 to corner 1 (turned by axis_angle); local z is the normal, pointing up for non-vertical surfaces.

#Supports (six degrees of freedom)

A support fixes global translations and rotations, written as six digits ux uy uz rx ry rz; 1 = fixed, 0 = free.

Support fix Use
Fixed (clamped) 111111 column base on a stiff foundation, cantilever root
Pinned 111000 column base with an anchor-bolt connection, simple bearing in 3D
Roller in X 011000 expansion bearing (free to slide in X)
Vertical only 001000 bearing on a wall, needs other supports for stability

A structure needs enough restraints for every rigid-body motion (3 translations, 3 rotations); otherwise the analysis reports a mechanism. Springs (spring id) replace rigid digits with a stiffness.

#Local axes of a member

Releases, member loads in local directions, sections and results use the member's own axes. Select a member to see them (x red, y green, z blue, at its middle); Solid shows the section the same way round.

  • x runs along the member, from its start to its end (Reverse direction swaps them).
  • z points up for every member that is not vertical: global Z, made square to x. The section's depth h lies along z, so an IPE beam stands upright.
  • y = z × x, sideways; the section's width b lies along y.
  • Vertical members (columns): y = x × global X, z = x × y. For a column drawn upwards, y is global Y and z points to −X.
  • roll (degrees) turns y and z about x: roll 90 lays a beam on its side, a column turns its strong axis to the other direction. A reference vector local_axis sets z directly instead.
  • The rule is the engine's (Nextra Design), so the same model gives the same axes in Nextra Design, Rhino and here.

A selected beam with its local axes: x along it, z up, y sideways

#Member end releases

Releases free internal forces at a member end, written as six local digits ux uy uz rx ry rz (the same order as N, Vy, Vz, T, My, Mz); 1 = released, 0 = connected. Keywords: fixed (all connected), pinned, auto (default).

  • 000011 frees both bending moments at that end (a simply supported beam end in 3D, keeping torsion).
  • 000111 frees torsion too.
  • auto: beam-role members get pinned span ends, a cantilever root without a back span stays fixed, collinear beams joined end to end act as one continuous beam; other members follow the joint rule (timber pinned at joints, other materials rigid).
  • Releasing too much (for example torsion at both ends, or every end of a joint) makes a mechanism.

#Load cases and categories

Each load belongs to a load case; each case has a category that sets its partial and ψ factors. Category ids of the EN annex:

Category id Meaning Typical imposed load (EN 1991-1-1, recommended)
G permanent (self-weight, finishes) — (self_weight: true adds members and surfaces automatically)
A-floors domestic / residential floors 1.5–2.0 kN/m² (EN 2.0)
A-stairs stairs 2.0 kN/m²
A-balconies balconies 2.5–4.0 kN/m² (EN 2.5)
B-offices offices 2.0–3.0 kN/m² (EN 3.0)
C1-tables areas with tables (cafés, schools) 2.0–3.0 kN/m²
C3-no-obstacles areas without obstacles (halls) 3.0–5.0 kN/m²
D1-retail general retail 4.0–5.0 kN/m²
E1-storage storage 7.5 kN/m²
H-roof roofs not accessible except for maintenance 0.0–1.0 kN/m² (EN 0.4)
Snow snow from EN 1991-1-3 and the site
Wind wind from EN 1991-1-4 and the site
E-seismic seismic from EN 1998

Use these exact ids (for example Wind, not W).

#Combinations (EN 1990)

With auto_combinations: true the engine builds the combinations from the cases and categories.

Ultimate limit state, persistent design situation (EN recommended):

  • 6.10: 1.35 G + 1.5 Q₁ + Σ 1.5 ψ₀ Qᵢ
  • 6.10a / 6.10b (the less favourable of): 1.35 G + Σ 1.5 ψ₀ Q — and — 0.85 × 1.35 G + 1.5 Q₁ + Σ 1.5 ψ₀ Qᵢ
  • Favourable permanent load: γG = 1.0.

Serviceability: characteristic G + Q₁ + Σ ψ₀ Qᵢ; frequent G + ψ₁ Q₁ + Σ ψ₂ Qᵢ; quasi-permanent G + Σ ψ₂ Q.

ψ factors (EN 1990 Table A1.1):

Category ψ₀ ψ₁ ψ₂
A domestic, B offices 0.7 0.5 0.3
C congregation, D shopping 0.7 0.7 0.6
E storage 1.0 0.9 0.8
H roofs 0 0 0
Snow (sites ≤ 1000 m) 0.5 0.2 0
Wind 0.6 0.2 0

#Materials (common values)

Material Strength E (N/mm²) Weight
Steel S235 / S355 (EC3) fy = 235 / 355 210 000 78.5 kN/m³
Concrete C25/30, C30/37 (EC2) fck = 25 / 30 31 000 / 33 000 (Ecm) 25 kN/m³ reinforced
Glulam GL24h / GL28h (EC5) fm,k = 24 / 28 11 500 / 12 600 (E0,mean) about 4.2–4.6 kN/m³
Softwood C24 (EC5) fm,k = 24 11 000 about 4.2 kN/m³

Name materials by grade (S355, C30/37, GL24h) with code EC3, EC2 or EC5; sections by profile (IPE300, HEA200) or as rectangles (GL 140x450, RC 300x300) in mm.

#Utilisation and checks

  • Utilisation u = design effect / design resistance. u ≤ 1.0 passes; the app shows u > 0.9 as close (amber) and u > 1.0 as failing (red). u_max is the governing value of the model.
  • Check families: axial; bending + axial; buckling (flexural); lateral-torsional buckling (LTB); shear; torsion; deflection.
  • Deflection limits are set by the annex and the project; common values: beams L/250 (quasi-permanent, total), L/300 to L/500 where brittle finishes or partitions are carried, cantilevers 2 × those (L/125 for L/250).

#Preliminary sizing (rules of thumb, preliminary only)

Element Depth ≈
Steel I-beam, simply supported span / 20 (IPE); span / 25 for light loads
Steel column, few storeys HEA / HEB 200–300 for 3–4 m storey height and moderate loads
Concrete slab, one-way, simply supported span / 25 to span / 30
Concrete slab, two-way continuous span / 35
Concrete beam span / 12 to span / 15
Glulam beam, simply supported span / 17
Timber joist span / 20

#Common modelling mistakes

  • Members that cross without a shared point are not connected (unless connect_crossings applies): use Intersect (Geometry → Edit) or place a point.
  • Coordinates within the tolerance (1 mm) are merged into one point on import; larger gaps stay separate members (Weld points merges them later).
  • A slab must stay flat; moving one corner bends it (the app warns).
  • Every material, section and load case used must be defined in the model.
  • Missing horizontal restraint (all pinned bases and pinned beam ends) makes a mechanism.
  • Loads on the wrong case category get the wrong factors (for example wind as Q imposed).
  • Photo-derived dimensions, supports and loads are assumptions until confirmed.