Skip to content
Nextra

Modelling

Loads

Load cases, groups, EN 1990 combinations, load panels, snow and automatic wind.

Loads belong to load cases. Each case has a category from the national annex. The category sets the combination factors and the load duration. The combinations are then built from the cases.

#Load cases

In the Loads tab, use "Edit load cases". Each case has an id, a category and a self-weight tick. In text form this is G=G+sw; Q=A-floors; S=Snow; W=Wind. A new file starts with G=G+sw; Q=A-floors. A load that uses a case you have not defined is an error.

#Putting loads on objects

Load How
Member load (kN/m) NxLoad on a curve, for example case Q, value 0,0,-3
Surface load (kN/m²) NxLoad on a surface
Nodal load (kN) NxLoad on a point
Load panel Elements tab, type Load panel
Free line or point load Elements tab

Values are global vectors. Gravity is 0,0,-q. Mode Add keeps existing loads. Mode Replace overwrites them.

#Load groups

Drag a case onto a group in the Loads tab. A group sets the category, the factors ψ0, ψ1 and ψ2, the load duration and, if you want, γ.

  • Independent: the cases are separate actions that share the values.
  • Act together: one action, every case at the same factor.
  • Mutually exclusive: one case at a time.

#Combinations

No combinations are made by themselves: press Create combinations… (Loads › Combinations) to have the national annex generate the EN 1990 set, or add your own rows. Without any combination each load case is designed on its own (ULS = γ × the case, SLS = 1.0 × the case), with a warning.

In the combination table the imperfection IMP is a 1 / 0 value in every ULS row (0 = without it); with several IMP directions each direction has its own column (1, 0 or auto).

Kind EN 1990
ULS 6.10, or 6.10a and 6.10b
ULS accidental (fire only) 6.11b
ULS seismic (response spectrum only) 6.12
SLS characteristic 6.14b
SLS frequent 6.15b
SLS quasi-permanent 6.16b

The annexes shipped are EN, NL, UK and DE. "Create combinations" in the Loads tab chooses the rules, the SLS kinds and the imperfections.

:::note Check the factors The combination factors for the UK and DE annexes are copies of the EN values. The NL values come from a reference workbook. All of them are flagged for verification in the data files. :::

#Imperfections

A switch adds equivalent horizontal forces to the ULS combinations. They are not a load case of their own.

#Load panels

A load panel is an area without stiffness. It carries area loads to the members under it.

  • Two-way: each part of the area goes to the nearest member.
  • One-way: the load splits between the members on each side of the span by the lever rule.
  • Plate: the load goes through a plate held along the members (its reactions become the member loads). Use it for irregular panels, openings and panels not supported all round. It is slower, so it is off by default.
  • Pressures per face: on a mesh load panel, Face factors (Nx_FaceFactors) gives one factor per mesh face, for example wind tunnel or CFD pressure coefficients. Each face carries q x its factor.
  • Targets default to the members within the tolerance (0.05 m). Give explicit targets for panels above their beams or steeper than 30 degrees.
  • After a run, the Loads tab shows the share per member and any lost load.

#Load direction and snow

Panel loads can be global, projected or local. Snow is a category. You enter it yourself as a projected load, for example S: -0.8 projected z. The examples use 0.8 kN/m². A negative value acts towards the negative axis.

#Wind

The Wind card in the Loads tab takes the peak velocity pressure qp. With the Dutch annex, qp is calculated when you leave it blank. For other annexes you enter qp.

Automatic wind builds the wind load from the outer load panels and surfaces. It uses the zones and pressure coefficients of EN 1991-1-4 Tables 7.1 to 7.5. The preview lists each generated case per direction. "Bake zones" writes the zones into Rhino as named meshes. You can replace the coefficient tables with a CSV.

Last updated 4 Nov 2026