Skip to content
Nextra

Design

Concrete design (EN 1992)

The EC2 beam, column, slab, punching, detailing and long-term checks.

Concrete is checked to EN 1992-1-1, with fire to EN 1992-1-2. Design uses concrete classes C20/25 to C50/60 and reinforcement B500A, B500B and B500C.

If you give reinforcement, u is the required area divided by the provided area. If you give none, u is the required area divided by the maximum, and the design lists what to provide.

#Beams and columns

Members must be rectangular.

The effective depth uses the member's own bar and link sizes when you give them (Design attributes › Concrete, rebar preferences such as bottom=12; top=12; links=0); otherwise the EC2 settings (link 8 mm, bar 16 mm). The crack width uses the same bar size.

Check Clause What it checks
Longitudinal bars 6.1, 9.2.1.1 Bottom and top reinforcement for M and N, minimum and maximum
Columns 5.8.8, 6.1 Imperfection, slenderness, second order by nominal curvature
Strut crushing 6.2.3 Maximum shear resistance
Shear links 6.2.3 Links, with the shift rule of 9.2.1.3
Crack width 7.3.4 Quasi-permanent, per station
Deflection 7.4 Analysis stiffness, and cracked long-term deflection to 7.4.3

#Slabs and walls

Surfaces use Wood-Armer design moments and membrane forces. You get the reinforcement area per metre, top and bottom, in x and y. The checks include:

  • minimum and maximum reinforcement (9.3.1.1),
  • shear without links (6.2.2),
  • crack width (7.3.4),
  • cracked long-term deflection (7.4.3),
  • a warning when compression reinforcement is needed.

The contours in Rhino show the bar areas, crack width, shear and utilisation.

#Punching shear

Punching is checked to 6.4 at columns, walls and piles. It covers openings, edge and corner positions, shear reinforcement and footings. You can use the prEN 1992-1-1:2023 method (8.4) instead. The control perimeters are drawn in Rhino.

Beam-supported columns are not checked. There is no input for punching reinforcement. The required reinforcement is reported.

#Detailing

The design selects bars, links and meshes. It handles anchorage and laps (8.4, 8.7), bar layout per span and a bar schedule with quantities. Beam rules follow 9.2 and column rules follow 9.5. The 3D bars can be drawn in Rhino.

#Cracked deflection methods

The parameter deflection_method has two values:

  • ec2: one analysis on the quasi-permanent combination with the 7.4.3 curvature law.
  • safe: load patterns in the style of CSI SAFE, with an extra check on the deflection after partitions are installed.

Both start from the gross section and do not apply ACI modifiers, so cracking is never counted twice.

#Long-term analysis

The nonlinear long-term analysis covers cracking with tension stiffening, creep and shrinkage (EN 1992-1-1 3.1.4, Annex B, 7.4.3). It works only for rectangular EC2 members and standard EC2 surfaces. Temperature adjustment of creep is not applied.

#Fire

Fire uses the tabulated data and the 500 degree isotherm method of EN 1992-1-2. Some tabulated limits, such as l0,fi up to 3 m and emax, are not checked.

#Curved shells

Design on curved shells is approximate. It works per element, and punching is checked in the local tangent plane.

Last updated 4 Nov 2026