Design
Design overview
How design codes are assigned, how to run the checks and how to read them.
Each design code is its own module. Every check stores its clause, the governing combination and a calculation trace. The utilisation u is the action effect divided by the resistance. A check passes when u is 1 or less.
#Which code checks which element
The code of an element comes from, in this order:
- The element's own setting (
Nx_DesignCode). - The design code of its material.
- The material code from the grade.
The value none means the element is analysed but not designed. The analysis is never affected.
| Code | Covers |
|---|---|
| EC5 | Timber, glulam and LVL members; CLT and laminated surfaces; stud walls and joist floors |
| EC3 | Steel catalogue profiles |
| EC2 | Rectangular concrete beams and columns; slabs and walls; punching |
| Bamboo | ISO 22156 culm members |
| Earth | NZS 4297 piers and wall strips |
#Run the checks
- Run the analysis first, or let the design run it.
- Open the Design group.
- Pick the codes with the chips.
- Press "Run design checks".
The design works on the stored analysis. If the model and analysis options did not change, the model is not analysed again. The report notes "design on the stored analysis".
#Read the results
The Design tab has a member list that you can sort and filter. It shows the utilisation and the governing check with its clause. Click a member to see:
- diagrams and u along the member,
- the hand check,
- the full calculation trace, with inputs, formulas, substituted values and clause numbers.
The viewport colours elements by utilisation. For concrete it also draws rebar and punching perimeters.
Design results of (top of Design results): Critical shows the governing combination of every check. Load cases, ULS or SLS then lets you pick one load case or one combination: every element shows its utilisation for that alone, in the table and in the viewport colours. A load case alone means ULS = γ × the case and SLS = 1.0 × the case; it works also when the model has combinations. Concrete elements show the checks the chosen combination governs in the full design, because their reinforcement is designed for all combinations together.
#Parameters
Every choice a code leaves open is a parameter, such as deflection limits or crack width limits. Parameters are layered:
- Bundled defaults.
- Your own copy for this PC.
- Settings in the model.
In the Design tab, changed values are shown in bold. "Reset to recommended values" restores the defaults.
#Deflection spans
Spans run between supports and columns. A free member end is a cantilever. In auto mode the chord and the cantilevers are checked, and the largest deflection governs. Columns and steep members have no span check.
#More checks
| Check | Notes |
|---|---|
| Fire | Turn on in the Design tab with a duration from R15 to R120. It uses the ISO 834 standard fire |
| Connections | Fasteners between members, using forces from every ULS combination |
| Environment | Mass, MKI and GWP per element. These are indicative defaults, not an official MPG |
| Optimisers | One per code. Each picks the lightest candidate that passes, then re-analyses |
#Code pages
Last updated 4 Nov 2026