Skip to content
Nextra

Design

Verification

How the engine and the design checks are compared with Nextra Design, OpenSees and hand calculations.

Nextra.fem is checked in three ways. The test projects are in the source repository (Tests/EngineComparison, Tests/DesignComparison, Tests/DesignCore).

#The engine

The same models are solved by Nextra.fem, by Nextra Design and by OpenSees, and compared with closed-form solutions:

Case Result
Cantilever, tip loads in both planes equal to the Timoshenko closed form (relative error 4e-16)
3D frames: rigid joints, pinned beams with line loads, springs displacements and reactions equal to Nextra Design and OpenSees (errors below 2e-12)
Simply supported plate, shell elements equal to Nextra Design and OpenSees (errors below 2e-13)
Column with P-Delta within 1.6e-4 of the exact solution

#The design checks

About 4,000 cases were run through the Nextra.fem design checks and through Nextra Design with the same input, then compared value by value: steel (classification, section checks, buckling factors, M_cr, Annex A and B interaction), timber (all factors and checks, EN and NL annex) and concrete (reinforcement, shear, crack width, Wood-Armer moments). Every difference was traced to a clause and checked against the Eurocode text. The clear differences were corrected in 1.0.4; the rest are method choices (for example Annex A or B, the simplified slab strip) and are listed in the test report.

#Hand checks

The examples carry simple checks: qL²/8 for the beam, the EC5 utilisation of the timber beam by hand (0.895), the slab deflection against a plate table (+1.8 %).

Last updated 9 Nov 2026