Reference
Scope and limitations
What Nextra.fem is for, what it does not do, and when to use Nextra Design.
Nextra.fem is for the early design: quick models, sizes and checks while the design still changes. It is not a full design package.
| Not in Nextra.fem | Where to do it |
|---|---|
| Second-order effects of slender concrete columns (EC2 5.8) | Non-Linear Analysis with P-Delta, or Nextra Design |
| Material non-linearity, construction stages, response spectrum | Nextra Design |
| Connections, punching, fire, long-term concrete deflection | Nextra Design |
| Angles and channels in lateral torsional buckling | Nextra Design |
Other points to know:
- The section library is a selection (for example IPE and HEA up to 200 mm). Use Cross Section for any other size.
- Rolled I sections are modelled from their plates without the root radius, so their area and stiffness are a few percent low; this is on the safe side.
- The hardwood grades D18 to D70 are marked VERIFY: check the values against EN 338:2016.
- The Nvidia Warp GPU solver is experimental and works on Windows with an Nvidia card only.
- The Mac version is new. Please report anything that looks wrong.
Check your results with simple hand calculations, and use Nextra Design for the final design.
Last updated 9 Nov 2026