Skip to content
Nextra

Reference

Scope and limitations

What Nextra.fem is for, what it does not do, and when to use Nextra Design.

Nextra.fem is for the early design: quick models, sizes and checks while the design still changes. It is not a full design package.

Not in Nextra.fem Where to do it
Second-order effects of slender concrete columns (EC2 5.8) Non-Linear Analysis with P-Delta, or Nextra Design
Material non-linearity, construction stages, response spectrum Nextra Design
Connections, punching, fire, long-term concrete deflection Nextra Design
Angles and channels in lateral torsional buckling Nextra Design

Other points to know:

  • The section library is a selection (for example IPE and HEA up to 200 mm). Use Cross Section for any other size.
  • Rolled I sections are modelled from their plates without the root radius, so their area and stiffness are a few percent low; this is on the safe side.
  • The hardwood grades D18 to D70 are marked VERIFY: check the values against EN 338:2016.
  • The Nvidia Warp GPU solver is experimental and works on Windows with an Nvidia card only.
  • The Mac version is new. Please report anything that looks wrong.

Check your results with simple hand calculations, and use Nextra Design for the final design.

Last updated 9 Nov 2026