Skip to content
Nextra

Design

Design checks

Steel (EC3), timber (EC5) and concrete (EC2) checks, Design View and the report.

The design components take the solved model (best: the Model output of Beam View) and give the utilisation of every element. Connect their MModel output to Design View to see it, and to Report for an HTML report of every check.

#Steel: EC3 Steel Design (EN 1993-1-1)

  • Section classification (5.5) and cross-section resistance (6.2): N, My, Mz, Vy, Vz, T and their interaction.
  • Member stability (6.3): flexural buckling, lateral torsional buckling with C1 from the moment diagram, N + M interaction with Annex A (default) or Annex B.
  • LTB load position (Options menu): Top (default), Centre or Bottom. A load on the top flange lowers M_cr (NCCI SN003, C2 z_g). It is applied to I sections and channels that carry a load along the span.
  • Rolled IPE, HEA, HEB and HEM sections use their catalogue root radius in the classification.
  • Deflection (SLS) against L/x.

#Timber: EC5 Timber Design (EN 1995-1-1)

  • Tension, compression, bending, shear and torsion, with k_mod from the load duration and k_h from the section size.
  • Column buckling and lateral torsional buckling, including the Dutch annex rule for G0,05.
  • Instantaneous, final and net final deflection with k_def (see ULS and SLS below).
  • Softwood, glulam, LVL and hardwood D18 to D70; national annexes EN, NL, UK, DE.

#Concrete: EC2 Concrete Design (EN 1992-1-1)

  • Beams and columns: bending and axial reinforcement, shear links (variable strut angle), torsion, crack width (7.3.4), span / depth.
  • Slabs and walls: Wood-Armer design moments and reinforcement per direction and face.

:::warning Slender concrete columns Second-order effects of slender columns (EN 1992-1-1 5.8) are not in the column check. Use the Non-Linear Analysis with P-Delta, or check them in Nextra Design. :::

EC5 utilisation of a hardwood floor beam

#ULS, SLS and what Design View shows

Every combination keeps the limit state it was made with (ULS, SLS characteristic, frequent or quasi-permanent). With nothing wired into a design's ULS / SLS inputs, the design sorts them itself:

Check Uses
Strength and stability (ULS) the ULS combinations
Deflection (SLS), EC3 the SLS combinations, w against L / limit (2L for a cantilever)
Deflection (SLS), EC5 characteristic → w_inst; quasi-permanent → w_qp. w_fin = w_inst + k_def · w_qp = w_G(1 + k_def) + w_Q,1(1 + ψ2,1 k_def) + Σ w_Q,i(ψ0,i + ψ2,i k_def) (EN 1995-1-1 2.2.3(5)); w_net,fin = w_fin − w_c (EN 1995-1-1 7.2, w_c = the precamber setting, default 0). Without quasi-permanent combinations w_qp = w_inst (ψ2 taken as 1, on the safe side); use Characteristic + quasi-permanent for the exact value
Only load cases, no combinations each case is checked as it is (no partial factors) and a remark says so; no SLS check

Wired inputs win over the sorting. Design View > Display > Show: Critical (the higher of ULS and SLS, the default), ULS, SLS, or one load case or combination. The legend title and the component message name the choice. The load cases on their own are checked only for this list; they do not count in ULS, SLS or Critical.

#Deflection: what is measured and how to see it

  • Vertical deflection only (the Z part). Columns - members steeper than 45° - are not checked.
  • Relative to the straight line between the span's displaced ends, so support settlement does not count. A cantilever is measured from its supported end.
  • Per span: between supports, columns, kinks, section changes or free ends - not per drawn line or polyline piece. Beams framing in from the side do not cut a span, so a primary beam carrying secondary beams is checked over its full length; each secondary beam spans between the beams it sits on. To measure it otherwise, Element 1D > Options > deflection span: auto (this rule, default), piece (each drawn line or polyline piece) or polyline (the whole polyline, split where it turns by more than 45°).
  • EC5 also gives the parts of EN 1990 A1.4.3 as EC5 reads them: w1 = permanent + quasi-permanent variable load, w2 = k_def · w1 (creep), w3 = w_inst − w1 (the rest of the variable load); w_fin = w1 + w2 + w3.
  • Design View > Result: Utilisation (default), or the checked deflection w_inst, w_fin, w_net,fin, w1, w2 or w3 as a contour along the beams (k_def included), with a tag at the largest value, for example w_fin = 7.1 mm = L/706. Members that are not checked are grey.

#Reading the log

The Logs output of each design component lists every check of every element with its clause, for example 6.3.3 (6.61) = 0.412. The governing check is named at the end.

Last updated 9 Nov 2026