Modelling
Loads and combinations
Self weight, beam and shell loads, load categories and durations, automatic EN 1990 combinations.
Every load belongs to a load case (for example G, Q, W). Loads with the same case name are added together into one case. Results are given per case and per combination.
The usual chain is:
- Load Case sets up a case: its name, its category and its duration.
- Wire it into the Case input of Basic Load, Beam Load or Shell Load. The load takes the case's name, category and duration. Several loads can use the same Load Case; they are added together.
- Pass all loads to Assemble Model and to Auto Load Combinations, and its combinations to Combo of Assemble Model.
#Load Case
| Setting | What it does |
|---|---|
| Name (input N) | The case name. Loads with the same name are one case |
| Category | Permanent (Dead), imposed A to H, snow, wind, temperature: the ψ factors of the combinations, from the design code of Global Settings |
| Duration | Auto, Permanent, Long, Medium, Short, Instantaneous: k_mod in the timber checks. Auto takes Permanent for Dead, Short for snow and wind, Long for storage (E) and Medium for other imposed loads |
The component shows the case as Q (B, Medium). You can still type a case name into Case and set Cat and Dur on the load itself; a wired Load Case overrides them.
#Load components
| Component | What it makes |
|---|---|
| Basic Load | Self weight (Grav, a vector: (0, 0, −1) is gravity) and point loads at nodes |
| Beam Load | Distributed, point and prestress loads on beams. F is a vector in kN/m (distributed) or kN (point); t0 and t1 are the start and end as a fraction of the length |
| Shell Load | Pressure on a mesh or on shells (kN/m², a vector), one-way or two-way panel loads, shell prestress |
Loads are drawn by Model View on the deformed shape, so an arrow always sits on the element it acts on.
#Category and duration
Without a Load Case component, set them on the load:
- Cat (category) sets the ψ factors of a variable load: 0 Dead, 1 to 8 categories A to H, 9 to 11 snow, 12 wind, 13 temperature. Load Info lists them with their ψ0, ψ1 and ψ2.
- Dur (duration: Permanent, Long-term, Medium-term, Short-term, Instantaneous) sets k_mod in the timber checks.
#Combinations
- Auto Load Combinations makes the EN 1990 combinations from the loads: ULS (6.10, or 6.10a/b with the national annex) and SLS characteristic, frequent and quasi-permanent. Pick the limit-state set in its list, or ULS + SLS: the ULS set and the SLS combinations chosen in the second list (Characteristic by default; Frequent, Quasi-permanent, Characteristic + quasi-permanent, All three). SLS combinations are named "SLS char: …", "SLS freq: …", "SLS qp: …". Quasi-permanent combinations use ψ2 for every variable action. The designs sort the combinations by their limit state (see Design checks).
- Loads of one case must have one category. When they differ, Auto Load Combinations warns and uses the first.
- Manual Load Combinator defines one combination with your own factors.
Connect the combinations to Combo of Assemble Model. The analysis solves every case and every combination.